SikaSwell® S-2
Hydrophilic, swellable joint sealant
SikaSwell® S-2 is a 1-part, hydrophilic polyurethane sealant that expands upon contact with water, effectively sealing construction joints and penetrations in concrete structures. It is used to adhere SikaSwell® A, SikaSwell® P profiles, and Sika® Hydrotite CJ-Type to the concrete structure.
- 1-part, easy and fast to apply
- Highly economical joint sealing solution
- Versatile solution for joints and details
- Optimised expansion rate
- Water-resistant (wet and dry cycles)
- Good adhesion to various substrates
- BBA Agrément Certificate with SikaSwell® A-2010
Usage
SikaSwell® S-2 is used to seal:- Construction joints
- Pipe and steel work penetrations through walls and floor slabs
- Around all types of penetrations and construction joints
- Construction joints in cable ducts
- SikaSwell® A
- SikaSwell® P
- Sika® Hydrotite CJ-Type
- Do not use SikaSwell® S-2 for movement joints.
- SikaSwell® S-2 is suitable for sealing against water pressures up to 2 bar. For pressures above 2 bar, use an alternative or supplementary Sika® joint sealing solution. For more information, contact Sika Technical Services.
Advantages
- 1-part, easy and fast to apply
- Highly economical joint sealing solution
- Versatile solution for joints and details
- Optimised expansion rate
- Water-resistant (wet and dry cycles)
- Good adhesion to various substrates
- BBA Agrément Certificate with SikaSwell® A-2010
Packaging
300 ml cartridges | 12 cartridges per box |
600 ml unipacs | 20 unipacs per box |
Refer to the current price list for available packaging variations.
Colour
Oxide red
Product Details
SUSTAINABILITY
Contributes towards satisfying Indoor Environmental Quality (EQ) Credit: Low-Emitting Materials under LEED® v4
Contributes towards satisfying Materials and Resources (MR) Credit: Building Product Disclosure and Optimization — Sourcing of Raw Materials under LEED® v4
Contributes towards satisfying Materials and Resources (MR) Credit: Building Product Disclosure and Optimization — Material Ingredients under LEED® v4
CERTIFICATES AND TEST REPORTS
Resistance to water pressure and durability SikaSwell® A2010, SikaSwell® S-2, BBA, Certificate No.13/4994
Composition
1-part polyurethane, moisture curing
Shelf life
12 months from date of production
Storage conditions
The Product must be stored in original, unopened and undamaged packaging in dry conditions at temperatures between +5 °C and +25 °C.
Always refer to packaging.
Refer to the current Safety Data Sheet for information on safe handling and storage.
Density
1.24 kg/L | (EN ISO 2811-1) |
System structure
STAND-ALONE SOLUTION
Sealant | SikaSwell® S-2 |
WITH A SIKASWELL® PROFILE
Adhesive | SikaSwell® S-2 |
Swelling profile | SikaSwell® A SikaSwell® P System Sika® Hydrotite CJ-Type |
Shore A hardness
30–50, unswollen (7 d / +23 °C / 50 % r.h.) | (EN ISO 868) |
Change of volume
Time | Demineralised water | 5 % saline solution |
1 day | ~25 % | ~8 % |
7 days | ~100 % | ~25 % |
30 days | ~200 % | ~50 % |
Note: The Product expands when it comes into contact with water, a process that takes several hours. When totally dry, the Product shrinks to its original dimensions. Upon further contact with water, the Product expands again.
Swelling pressure
The pressure developed by the material depends on the stiffness of the surrounding concrete structure. The stiffness is influenced by concrete quality, voids, gaps and other weaknesses. If the concrete structure is in perfect condition, the material can create a swelling pressure of > 10 bar.
Service temperature
Minimum | -20 °C |
Maximum | +50 °C |
Application
Sag flow
Tested at +23 °C / 50 % r.h. | < 2 mm |
Material temperature
Maximum | +35 °C |
Minimum | +5 °C |
Ambient air temperature
Maximum | +35 °C |
Minimum | +5 °C |
Substrate temperature
Maximum | +35 °C |
Minimum | +5 °C |
Substrate moisture content
Dry or matt damp. Do not apply in construction joints with standing water.
Curing rate
Cured 1 day at +23 °C / 50 % r.h. | ~2.0 mm |
Cured 10 days at +23 °C / 50 % r.h. | ~10.0 mm |
Skinning time
Tested at +23 °C / 50 % r.h. | 60 minutes |
Place SikaSwell® profiles onto SikaSwell® S-2 within a maximum of 30 minutes.
Consumption
Size of triangular section | 300 ml cartridges | 600 ml unipacs |
12 mm | 4.1 m | 8.2 m |
15 mm | 3.1 m | 6.2 m |
20 mm | 1.8 m | 3.6 m |
Consumption depends on the roughness and absorbency of the substrate.
Note: Consumption data is theoretical and does not allow for any additional material due to surface porosity, surface profile, variations in level, wastage or any other variations. Apply the Product to a test area to calculate the exact consumption for the specific substrate conditions and proposed application equipment.
SUBSTRATE QUALITY
The substrate must be sound, clean, dry or matt damp and free from all surface contaminants that could impair the adhesion of the sealant.
SUBSTRATE PREPARATION
EXISTING CONCRETE
Rough surfaces are susceptible to leaking. If the surface is too irregular for SikaSwell® S-2 to effectively level, the irregularities must be eliminated. Prior to applying SikaSwell® S-2 and the SikaSwell® A or SikaSwell® P profile or Sika® Hydrotite CJ-Type, smooth the area with a suitable Sika® leveling mortar or through mechanical means.
FRESHLY CAST CONCRETE
Freshly cast concrete can be smoothed with a batten where SikaSwell® S-2 is to be placed.
APPLICATION
IMPORTANT
Poor Product performance due to insufficient concrete covering the SikaSwell® profile or Sika® Hydrotite CJ-Type
The SikaSwell® profile or Sika® Hydrotite CJ-Type must be covered with concrete that withstands the pressure created when the SikaSwell® profile or Sika® Hydrotite CJ-Type expands. If the concrete cover is insufficient, in case of low density concrete or voids, the SikaSwell® profile or Sika® Hydrotite CJ-Type will not be able to perform its waterproofing function effectively.
- Place the SikaSwell® profile or Sika® Hydrotite CJ-Type in the centre of the covering concrete structure.
- In reinforced concrete, apply a minimum cover of 8 cm on both sides of the SikaSwell® profile or Sika® Hydrotite CJ-Type.
- In unreinforced concrete, apply a minimum cover of 15 cm on both sides of the SikaSwell® profile or Sika® Hydrotite CJ-Type.
SEALANT WITH A SIKASWELL® PROFILE
-
Apply the SikaSwell® S-2 adhesive in a narrow bed onto the prepared substrate, extruded in a triangular section ~12 mm wide and ~12 mm deep.
Note: Extrude enough material to level the roughness of the substrate. -
Press the SikaSwell® profile or Sika® Hydrotite CJ-Type firmly into the freshly applied SikaSwell® S-2.
Note: Place the SikaSwell® profile or Sika® Hydrotite CJ-Type within a maximum of 30 minutes (+23 °C / 50 % r.h.). Ensure that full and continuous contact between the SikaSwell® S-2 adhesive and both the SikaSwell® profile or Sika® Hydrotite CJ-Type and the substrate is achieved. - Allow SikaSwell® S-2 to harden for at least 12 hours before placing concrete. For pouring height > 50 cm, allow SikaSwell® S-2 to harden for at least 24 hours before placing concrete.
- Protect the SikaSwell® S-2 and the SikaSwell® profile or Sika® Hydrotite CJ-Type against water – for example, rain – until the concrete is placed.
- When placing the concrete, compact the fresh concrete well around the SikaSwell® profile or Sika® Hydrotite CJ-Type to achieve dense concrete without any honeycombing or voids.
SEALANT AS STAND-ALONE SOLUTION
Structure thickness | Size of triangular section |
< 20 cm | 12 mm |
20–30 cm | 15 mm |
30–50 cm | 20 mm |
-
Apply SikaSwell® S-2 in a triangular bead onto the prepared substrate.
Note: Use a triangular nozzle, or cut the nozzle, to obtain a regular triangular extrusion section. Apply SikaSwell® S-2 according to the dimensions specified in the table. - Ensure that full and continuous contact between the SikaSwell® S-2 and the substrate is achieved.
- Allow SikaSwell® S-2 to harden for at least 12 hours before placing concrete. For pouring height > 50 cm, allow SikaSwell® S-2 to harden for at least 24 before placing concrete.
- Protect the SikaSwell® S-2 against water – for example, rain – until the concrete is placed.
CLEANING OF EQUIPMENT
Clean all tools and application equipment with Sika® Colma Cleaner immediately after use. Hardened material can only be removed mechanically.