Thermal insulation is one of the most important system components in a roof, creating a comfortable environment inside the building by protecting it from heat and cold while also helping to reduce heating and cooling energy costs. The importance of thermal insulation has increased recently mainly due to changing insulation standards worldwide, which put higher demands on the thermal resistance of building structures to reduce energy loss for heating or cooling.

Insulation types used in flat roofing systems should have not only high thermal characteristics but also sufficient mechanical properties to be able to withstand loads (e.g. snow loads, ballast, limited pedestrian traffic for maintenance, moisture in inverted roof build ups, etc.).

Common Types of Thermal Insulation Used on Roofs

PIR insulation board
Polyurethane Foam (PIR/PUR)

PIR is a thermal insulation board produced in a chemical process from rigid polyurethane (PU) foam combined with an isocyanurate catalyst. This is a very universal and efficient solution for all kinds of exposed roofs. It is one of the most suitable insulation types for adhered roof systems and can also be used in ballasted roof applications.

Mineral wool insulation board
Stone Wool

Stone wool, also known as rock wool, is a type of mineral wool insulation produced from basalt stone fibers. It is one of the most common solutions for exposed mechanically fastened roofs, especially where very high fire resistance is required.

EPS insulation board
Expanded Polystyrene (EPS)

EPS is a thermal insulation board produced from expanded polystyrene granules. It is one of the most cost efficient solutions for exposed and ballasted roofing systems.

XPS insulation board
Extruded Polystyrene (XPS)

XPS is a thermal insulation board produced from polystyrene in an extrusion process. Due to its special characteristics, it is the ideal solution for inverted ballasted systems and utility roof decks. XPS can also be used in exposed roofing systems.

Advantages of PIR/PUR
  • Very good fire resistance (more than 250°C)
  • Extremely low thermal conductivity value of 0.023 – 0.028 W/m·K
  • High compressive strength in the range of 100 – 300 kPa, which is also sufficient for some ballasted applications
  • Lightweight in the range of 30 – 60 kg/ m3
Advantages of Stone Wool
  • Excellent fire resistance (up to over 1000°C), most stone wool products are classified as noncombustible
  • Low thermal conductivity value of 0.038 – 0.041 W/m·K
  • Compressive strength in the range of 40 - 80 kPa, which is sufficient for exposed roofing applications
  • Weight is in the range of 100 – 200 kg/m3

Advantages of EPS
  • Most of the products are self-extinguishing in fine
  • Low thermal conductivity value of 0.037 – 0.041 W/m·K
  • High compressive strength in the range of 100 – 250 kPa, which is also sufficient for some ballasted applications
  • Lightweight in the range of 20 – 40 kg/m3

Advantages of XPS
  • Almost zero water absorption
  • Most XPS products are self-extinguishing in fire
  • Very low thermal conductivity value of 0.034 – 0.038 W/m·K
  • Very high compressive strength in the range of 250 – 700 kPa which is sufficient for utility decks with high traffic
  • Lightweight in the range of 25 – 35 kg/m3

Comparison of Typical Thermal Insulation Types

FeaturesSikatherm PIR AL/GTMineral WoolEPS
Excellent thermal performance (1)  
Resistant to high temperature (≥ 200° C)  (2) 
High compression strength (≥ 100 kPa)  
Low water absorption capacity (≤ 10%) 
Lightweight  (3) 
Closed cell foam structure 
Direct contact allowed to PVC single-ply membrane 
Suitable for adhered roof systems 
Suitable for ballasted roof systems 
Suitable for green roof systems 
Suitable for use with liquid-applied membranes (LAM) (4)  
Insulation boards with rebated edges 
Resistance to warm bitumen 
Resistant to fungal growth 
Non-fibrous material (does not irritate the skin and cannot cause lung disease) 

NOTES: (1) Thermal conductivity value minimum 0.028 W/m·K   (2) Short time resistance   (3) Less than 60 kg/m3   (4) Only Sikatherm PIR GT allowed

PIR Has Many Advantages over Other Types of Thermal Insulation

  • Lower thickness compared to many other technologies - thinner thermal boards for same performance
  • Low density – ideal for renovation projects, less workmanship needed, adds minimal additional load to roof
  • Heat resistant up to 250 °C, does not melt, does not support spread of fire
  • PIR GT is “universal” (adhered, mechanically fastened, ballasted roofs)
  • Better compressive strength value than mineral wool
  • Excellent workability (does not irritate skin, easy to cut, lightweight boards are easy to transport, etc.)
  • Boards are available in tapered version
  • Compatible with PVC, LAM and most Sika roofing build-ups
  • Single-layer insulation
  • Less price sensitive compared to EPS or MW
  • Sikaplan / Sarnafil membranes can be laid directly on PIR board. Integrated facers on the boards prevent from direct contact between PVC and PIR foam.